• DocumentCode
    1997480
  • Title

    Time-delay compensation in detection electronics of fast scanning 2D SAW/BAW laser probe

  • Author

    Omori, Tatsuya ; Kashiwa, Keisuke ; Hashimoto, Ken-Ya ; Yamaguchi, Masatsune

  • Author_Institution
    Grad. Sch. of Eng., Chiba Univ., Chiba, Japan
  • fYear
    2009
  • fDate
    20-23 Sept. 2009
  • Firstpage
    1644
  • Lastpage
    1647
  • Abstract
    This paper describes the enhancement of the measurement speed by compensating delay time caused in detection electronics. As a demonstration, an SAW field in a one-port resonator was visualised by the developed system. It is shown that under optimal compensation, the influence of the delay time can be dissolved, and that a high quality image is obtained even when the two-way data scan is applied. Compared with the conventional system, the sampling rate was made double.
  • Keywords
    acoustic variables measurement; bulk acoustic wave devices; surface acoustic wave devices; detection electronics; fast scanning 2D SAW/BAW laser probe; measurement speed enhancement; one port resonator; time delay compensation; Acoustic waves; Delay effects; Image sampling; Optical resonators; Probes; Radio frequency; Sagnac interferometers; Surface acoustic waves; Time measurement; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441688
  • Filename
    5441688