DocumentCode
1998396
Title
Landfill gas field pump test in one old landfill, China
Author
Lan, Jiwu ; Li, Yuchao ; Zhan, Liangtong ; Chen, Yunmin
Author_Institution
MOE Key Lab. of Soft Soils & Geoenviromental Eng., Zhejiang Univ., Hangzhou, China
fYear
2011
fDate
16-18 Sept. 2011
Firstpage
4552
Lastpage
4556
Abstract
One field pump test with passive and active condition was conducted in Qingxilu landfill, Hefei city. In passive condition test, the water level and LFG quality of the constructed extraction wells were tested, and it was revealed that the high water level lead to low LFG quality. Through the active pump test implemented in four extraction wells, the following discipline was discovered: (1) There was large volume LFG stored in waste body; (2) the LFG generation rate for the entire landfill above water level could be 1449m3/h at 50% methane in 2008. The Scholl-Canyon model was then employed to estimate annual LFG generation rate over a time period and it could be predicted that the actual LFG collection potential was more than 600 m3/h before 2015 without water drawdown, however, under condition of the water in waste body pumped out, the actual LFG collection potential would be more than 600 m3/h before 2020.
Keywords
filtration; fuel pumps; hydrocarbon reservoirs; waste; China; Hefei city; LFG quality; Qingxilu landfill; Scholl-Canyon model; extraction wells; landfill gas field pump test; methane; Cities and towns; Fluid flow; Fluid flow measurement; Monitoring; Pollution measurement; Pressure measurement; Probes; Landfill gas; extraction well; field pump test; old landfill; water level;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Control Engineering (ICECE), 2011 International Conference on
Conference_Location
Yichang
Print_ISBN
978-1-4244-8162-0
Type
conf
DOI
10.1109/ICECENG.2011.6058210
Filename
6058210
Link To Document