• DocumentCode
    1998576
  • Title

    The research of arc-proofness of set tools for 110-220 kV live line works

  • Author

    Kolker, D.

  • fYear
    1993
  • fDate
    12-17 Sep 1993
  • Firstpage
    387
  • Lastpage
    391
  • Abstract
    This paper presents the results of studies on the arc-proofness of insulating booms of aerial platforms for live line works. The data obtained with 5-20 kA power arcs applied for 1.5-0.1 sec, show acceptable arc-proofness of tested insulating boom samples and full-scale models as well as their ability to withstand nominal voltage or even switching overvoltages after such an arc, if autoreclosing occurs during live line work. The obtained results make possible further improvements of existing telescopic platforms
  • Keywords
    Conductors; Copper; Dielectrics and electrical insulation; Glass; Insulator testing; Power system modeling; Protection; Surges; System testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Transmission and Distribution Construction and Live Line Maintenance, 1993. Proceedings from ESMO-93., Sixth International Conference on
  • Conference_Location
    Las Vegas, NV
  • Print_ISBN
    0-7803-1340-2
  • Type

    conf

  • DOI
    10.1109/TDCLLM.1993.316234
  • Filename
    316234