DocumentCode :
1999399
Title :
A Network Analyzer Calibration using Redundancy
Author :
Sequeira, H.B. ; Trippe, M.W. ; Jakhete, R.
Author_Institution :
Martin Marietta Laboratories/Gamma Monolithics.
fYear :
1988
fDate :
12-15 Sept. 1988
Firstpage :
321
Lastpage :
326
Abstract :
A calibration procedure for phasor network measurements has been developed in which redundancy is exploited to: (i) provide integral calibration assurance, (ii) render the procedure tolerant to the measurement environment, and (iii) simplify the fabrication requirements on calibration standards, especially for monolithic devices. The measurement algorithm uses a known standard, an unknown standard, and a pair of offset transmission lines whose lengths are in a fixed known ratio, and outputs the calibration coefficients, the reflection coefficient of the unknown standard, and the loss and phase of the transmission lines. Furthermore, the procedure uses its built-in redundancy to furnish an indication of the nonsystematic errors in the calibration process. This technique is applicable to one-and two-port calibrations and is best suited for making phasor network measurements in monolithic environments.
Keywords :
Calibration; Fabrication; Length measurement; Loss measurement; Measurement standards; Phase measurement; Redundancy; Reflection; Standards development; Transmission line measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference, 1988. 18th European
Conference_Location :
Stockholm, Sweden
Type :
conf
DOI :
10.1109/EUMA.1988.333835
Filename :
4132523
Link To Document :
بازگشت