DocumentCode :
1999539
Title :
Improved estimation of parameters of the homodyned K distribution
Author :
Hruska, David ; Lavarello, Roberto ; Brien, William D O, Jr. ; Oelze, Michael L.
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Illinois at Urbana-Champaign, Urbana, IL, USA
fYear :
2009
fDate :
20-23 Sept. 2009
Firstpage :
2268
Lastpage :
2271
Abstract :
The amplitude distribution of the envelope of backscattered ultrasound depends on tissue microstructure. By fitting measured envelope data to a model, parameters can be estimated to describe properties of underlying tissue. The homodyned K distribution is a general model that encompasses the scattering situations modeled by the Rice, Rayleigh, and K distributions. However, parameter estimation for the homodyned K distribution is not straightforward because the model is analytically complex. Furthermore, effects of frequency-dependent attenuation on parameter estimates need to be assessed. An improved parameter estimation algorithm was developed to quickly and accurately estimate parameters of the homodyned K distribution, i.e., the ? (effective number of scatterers per resolution cell) and k (ratio of coherent to diffuse energy) parameters. Parameter estimates were found by fitting estimates of SNR, skewness, and kurtosis of fractional-order moments of the envelope with theoretical values predicted by the homodyned K distribution. The effects of frequency dependent attenuation were approximated by assuming a Gaussian pulse to determine the shift in center frequency of the pulse and hence change in volume of the resolution cell. Computational phantoms were created with varying attenuation coefficients and scanned using a simulated f/4 transducer with a center frequency of 10 MHz. An average of two scatterers per resolution cell (based on the phantoms with no attenuation) was used. The new estimation algorithm was tested and compared with an existing algorithm (based on the even moments of the homodyned K distribution). The new estimation algorithm was found to produce estimates with lower bias and variance. For example, for ? = 2 and k ranging from 0 to 2 in steps of 0.1, the average variance in the ? parameter estimates was 0.067 for the new algorithm and 0.42 for existing algorithm. For the k parameter estimates, the average variance was 0.0069 for the new algorith- - m and 0.048 for the old algorithm. In the simulations with no attenuation, the ? parameter estimate was 2.53?0.18. In the phantoms with a linear attenuation coefficient of 0.5 dB?MHz-1?cm-1, the estimate was 4.64?0.54. This compared well with the predicted ? value of 4.98.
Keywords :
acoustic signal detection; bioacoustics; biological tissues; biomedical ultrasonics; homodyne detection; medical signal detection; parameter estimation; ultrasonic scattering; backscattered ultrasound envelope amplitude distribution; coherent-diffuse energy ratio; computational phantoms; frequency 10 MHz; frequency dependent attenuation; homodyned K distribution; improved parameter estimation; parameter estimation algorithm; pulse center frequency shift; scatterer number; simulated f/4 transducer; tissue microstructure; Attenuation; Energy resolution; Frequency estimation; Imaging phantoms; Microstructure; Parameter estimation; Rayleigh scattering; Scattering parameters; Ultrasonic imaging; Ultrasonic variables measurement; Backscatter; Envelope Statistic; Tissue Characterization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium (IUS), 2009 IEEE International
Conference_Location :
Rome
ISSN :
1948-5719
Print_ISBN :
978-1-4244-4389-5
Electronic_ISBN :
1948-5719
Type :
conf
DOI :
10.1109/ULTSYM.2009.5441774
Filename :
5441774
Link To Document :
بازگشت