Abstract
Internal resistance, coefficient of Seebeck and coefficient of thermal conduct were measured and formulated in different temperature ranges based on theoretic model of output power for micro-thermoelectric generator. Max output power was measured with different number, different length of thermocouple and different temperature of heat and sink. The results show that the max output power increases when the length of the thermocouple decreases and will be optimized under certain average ratio. The max output power increases with the number of thermocouples in a certain range, and it is optimized under certain average temperature and difference of temperature. Micro-thermoelectric generate device was established based upon analysis results.
Keywords
Data analysis; Electrical resistance measurement; Heat sinks; Length measurement; Performance analysis; Power generation; Power measurement; Temperature distribution; Thermal conductivity; Thermal resistance; Fitting and analysis; Max output power; Micro-thermoelectric generator; Thermoelectric performance;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Automation, 2007. ICCA 2007. IEEE International Conference on
Conference_Location
Guangzhou
Print_ISBN
978-1-4244-0818-4
Electronic_ISBN
978-1-4244-0818-4
Type
conf
DOI
10.1109/ICCA.2007.4376346
Filename
4376346
Link To Document