DocumentCode :
2003822
Title :
Virtual laryngoscopy: feasibility studies by CT and MRI
Author :
Chen, Dongqing ; Li, Bin ; Roche, Patricia ; Huang, Wei ; Zhengrong Liang
Author_Institution :
Dept. of Radiol. & Comput. Sci., State Univ. of New York, Stony Brook, NY, USA
Volume :
3
fYear :
1999
fDate :
1999
Firstpage :
1583
Abstract :
Both computed tomography (CT) and magnetic resonance (MR) imaging protocols and a self-adaptive segmentation algorithm were employed to study the feasibility of virtual laryngoscopy. Several visualization techniques were utilized to achieve a real-time interactive inspection of the larynx. The developed virtual laryngoscopy was tested on 2 volunteers and 2 patients. Spiral CT protocol offers the advantage of high speed (less than 30 seconds of data acquisition) and high resolution (cubic voxel size of 0.3 mm), at the risk of radiation. Fast spoiled-GRASS MR pulse sequence provides a better tissue contrast and a reasonable signal-to-noise ratio, at the cost of lower resolution (of cubic voxel size of 1 mm) and longer acquisition time (close to 7 minutes). The segmentation algorithm performed consistently for the four studies and was not sensitive to motion artifacts in both CT and MR images. The visualization system could interactively navigate inside the larynx lumen with features of inspecting and zooming the geometry, exam the outside of the larynx with associated tissues labeled by different colors, and cut the larynx in any orientation to open the whole volume for a view of the inner surface. The examination of larynx was non-invasive, reproducible, and efficient. It demonstrated the feasibility of virtual laryngoscopy for diagnosis of laryngeal diseases
Keywords :
adaptive signal processing; biological organs; biomedical MRI; computerised tomography; image segmentation; medical image processing; virtual reality; 0.3 mm; 1 mm; 30 s; 7 min; CT; MRI; acquisition time; cubic voxel size; fast spoiled-GRASS MR pulse sequence; laryngeal diseases diagnosis; magnetic resonance imaging; medical diagnostic imaging; motion artifacts; radiation risk; real-time interactive inspection; reasonable signal-to-noise ratio; segmentation algorithm; tissue contrast; virtual laryngoscopy feasibility; visualization system; Computed tomography; Data visualization; Image segmentation; Inspection; Larynx; Magnetic resonance; Magnetic resonance imaging; Protocols; Signal resolution; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1999. Conference Record. 1999 IEEE
Conference_Location :
Seattle, WA
ISSN :
1082-3654
Print_ISBN :
0-7803-5696-9
Type :
conf
DOI :
10.1109/NSSMIC.1999.842863
Filename :
842863
Link To Document :
بازگشت