DocumentCode
2003881
Title
Communication interface dose rate hardening
Author
Claraz, J.L. ; Lalande, P. ; Gluck, D. ; Bredy, J. ; Deluchat, P.
Author_Institution
Tekelec Syst., Les Ulis, France
fYear
1993
fDate
13-16 Sep 1993
Firstpage
109
Lastpage
112
Abstract
An industrial electronic equipment has been hardened at low-cost, using 100% of standard parts, by solutions compatible with its initial design: the analysis of vulnerability, the selection of parts, nuclear event detector, peripheral architecture, circumvention
Keywords
military systems; radiation hardening (electronics); communication interface; dose rate hardening; industrial electronic equipment; nuclear event detector; parts selection; peripheral architecture; radiation hardening; vulnerability; Batteries; CMOS technology; Circuits; Content addressable storage; Context-aware services; EPROM; Modems; Photodiodes; Protection; Signal processing;
fLanguage
English
Publisher
ieee
Conference_Titel
Radiation and its Effects on Components and Systems, 1993.,RADECS 93., Second European Conference on
Conference_Location
St. Malo
Print_ISBN
0-7803-1793-9
Type
conf
DOI
10.1109/RADECS.1993.316545
Filename
316545