DocumentCode
2005348
Title
Measured performance of magnetron injection guns for gyrotrons
Author
Ives, R.Lawrence ; Marsden, David ; Collins, George ; Miram, George ; Gunther, Kim ; Curtis, Marc ; Borchard, Philipp
Author_Institution
Calabazas Creek Research, Inc. 690 Port Drive, San Mateo, CA 94404, USA
fYear
2008
fDate
22-24 April 2008
Firstpage
46
Lastpage
47
Abstract
Magnetron injection guns (MIGs) are a principle component in gyrotrons and gyroklystrons. The performance of the RF device critically depends on the performance of the MIG that provides the electron beam. Unfortunately, recent measurements indicate that MIGS often generate asymmetrical electron beams that can adversely impact the operation of the RF source. This presentation will describe the measurement facility and provide results from recent tests.
Keywords
Assembly; Cathodes; Electron beams; Guns; Gyrotrons; Klystrons; Probes; Radio frequency; Temperature measurement; Voltage; MIG; RF source; electron gun; gyroklystron; gyrotron; work function;
fLanguage
English
Publisher
ieee
Conference_Titel
Vacuum Electronics Conference, 2008. IVEC 2008. IEEE International
Conference_Location
Monterey, CA, USA
Print_ISBN
978-1-4244-1715-5
Type
conf
DOI
10.1109/IVELEC.2008.4556408
Filename
4556408