DocumentCode
2010845
Title
Clock accuracy analysis for a coherent IR-UWB system
Author
Wang, Xiaoyan ; Young, Alex ; Philips, Kathleen ; De Groot, Harmke
Author_Institution
Holst Centre, imec, Eindhoven, Netherlands
fYear
2011
fDate
14-16 Sept. 2011
Firstpage
440
Lastpage
444
Abstract
The performance of a duty-cycled coherent impulse radio UWB system is typically dominated by the accuracy of its timing references. In this paper, a timing analysis is presented for an IR-UWB system to specify the accuracy requirements for the internal clocks of the transceiver. A possible clock generation unit is proposed to realize the coherent reception and improve sensitivity and SNR performance. The analysis is performed for an IEEE802.15.4a compliant data packet, however, can be extended to other IR-UWB standards easily.
Keywords
Zigbee; clocks; radio transceivers; timing; ultra wideband communication; IEEE802.15.4a compliant data packet; clock accuracy analysis; clock generation; coherent IR-UWB system; coherent reception; timing references; transceiver; Modulation; Payloads;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultra-Wideband (ICUWB), 2011 IEEE International Conference on
Conference_Location
Bologna
ISSN
2162-6588
Print_ISBN
978-1-4577-1763-5
Electronic_ISBN
2162-6588
Type
conf
DOI
10.1109/ICUWB.2011.6058881
Filename
6058881
Link To Document