Title :
New progress of the digital electrical capacitance tomography system for gas/liquid two phase flow
Author :
Wang, Huaxiang ; Xin, Shan ; Zhang, Xuehui
Author_Institution :
Sch. of Electr. Eng. & Autom., Tianjin Univ., Tianjin
Abstract :
Electrical capacitance tomography (ECT) is gaining acceptance as a laboratory and industry tool to analyze gas/liquid two phase flow. To overcome the shortcomings of the existing analogue ECT system, a new 16-electrode digital electrical capacitance tomography system based on FPGA and DSP is designed. The new scheme can easily realize single frequency and multi-frequency excitation and demodulation. Furthermore, two kinds of methods for multi-frequency demodulation, DFT demodulation and digital quadrature demodulation, are discussed deeply. Static and dynamic experiments under condition of single frequency are carried out to verify the performance of the digital ECT system. Experimental results show that this system is of high precision and stability.
Keywords :
electric impedance imaging; field programmable gate arrays; flow visualisation; gases; tomography; two-phase flow; demodulation; digital ECT system; digital electrical capacitance tomography system; digital quadrature demodulation; field programmable gate arrays; gas-liquid two phase flow; multifrequency excitation; single frequency excitation; Automation; Chemical industry; Circuits; Demodulation; Electrical capacitance tomography; Electrodes; Field programmable gate arrays; Fluid flow; Frequency; Sensor arrays; DDS; DFT; ECT; FPGA; digital quadrature demodulation; multi-frequency; two phase flow;
Conference_Titel :
Imaging Systems and Techniques, 2009. IST '09. IEEE International Workshop on
Conference_Location :
Shenzhen
Print_ISBN :
978-1-4244-3482-4
Electronic_ISBN :
978-1-4244-3483-1
DOI :
10.1109/IST.2009.5071598