Title :
2D ECT with square sensor using Calderon´s method
Author :
Cao, Zhang ; Xu, Lijun ; Wang, Huaxiang
Author_Institution :
Sch. of Instrum. Sci. & Opto-Electron. Eng., Beihang Univ., Beijing
Abstract :
Calderon´s method was introduced to electrical capacitance tomography with square sensor in this paper. It is a direct algorithm of the image reconstruction, as no matrix inversion or iterative process is needed. It was implemented through numerical integration. Since the Gauss-Legendre quadrature was applied and can be predetermined, the image reconstruction process was fast and resulted in images of good quality. Simulated results validated the feasibility and effectiveness of Calderon´s method in electrical capacitance tomography with square sensor.
Keywords :
capacitive sensors; image reconstruction; integration; tomography; 2D square ECT sensor; Calderon method; Gauss-Legendre quadrature; electrical capacitance tomography; image quality; image reconstruction process; numerical integration; Capacitive sensors; Conductivity; Electrical capacitance tomography; Electrodes; Fluidization; Image reconstruction; Image sensors; Permittivity; Sensor phenomena and characterization; Sensor systems; Calderon´s method; electrical capacitance tomography; square sensor;
Conference_Titel :
Imaging Systems and Techniques, 2009. IST '09. IEEE International Workshop on
Conference_Location :
Shenzhen
Print_ISBN :
978-1-4244-3482-4
Electronic_ISBN :
978-1-4244-3483-1
DOI :
10.1109/IST.2009.5071600