DocumentCode :
2012146
Title :
Zero-overhead self test and calibration of RF transceivers
Author :
Nassery, Afsaneh ; Jae Woong Jeong ; Ozev, Sule
Author_Institution :
Electr. Eng., Arizona State Univ., Tempe, AZ, USA
fYear :
2013
fDate :
6-13 Sept. 2013
Firstpage :
1
Lastpage :
9
Abstract :
In this paper we present a self-test method for RF transceivers to determine IQ imbalance, time skews, IIP3, IIP5, AM/AM, and AM/PM distortion with no hardware overhead. The analysis is done through the loop-back set-up over two frames, each of which is 200us in duration. The overall measurement time is less than 10ms including the computation time. The determined parameters can be used for digital calibration, which greatly enhances reliability and yield by widening the tolerance of the parameters. We show through hardware measurements that the target performance parameters can be determined accurately and the EVM can be reduced more than 5 folds, making even highly impaired systems usable. The only additional component to enable our approach is an attenuator in the loop-back path, which can be placed outside the chip. Hence, we call this self test and calibration approach a zero overhead approach.
Keywords :
calibration; radio transceivers; reliability; AM-AM distortion; AM-PM distortion; EVM; IIP3; IIP5; IQ imbalance; RF transceiver calibration approach; digital calibration; loop-back path; loop-back set-up; reliability; target performance parameters; time 200 mus; time skews; zero-overhead self-test method; Calibration; Delays; Equations; Mathematical model; Radio frequency; Transceivers; Transmitters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Test Conference (ITC), 2013 IEEE International
Conference_Location :
Anaheim, CA
ISSN :
1089-3539
Type :
conf
DOI :
10.1109/TEST.2013.6651921
Filename :
6651921
Link To Document :
بازگشت