• DocumentCode
    2012840
  • Title

    Problematic aspects when using a LISN for converter EMI characterisation

  • Author

    de Beer, A.S. ; Wooding, G.N. ; van Wyk, J.D.

  • Author_Institution
    Group on Electron. Energy Process., Univ. of Johannesburg, Johannesburg, South Africa
  • fYear
    2013
  • fDate
    25-28 Feb. 2013
  • Firstpage
    633
  • Lastpage
    637
  • Abstract
    In this paper it is shown that conducted interference from a power converter differs when measured with and without a Line Impedance Stabilization Network (LISN). This is problematic as the true Electromagnetic Interference (EMI) of a converter is therefore difficult to characterize. Possible reasons for this difference are discussed showing to the influence of a LISN on measurements.
  • Keywords
    electromagnetic interference; power convertors; LISN; conducted interference; converter EMI characterisation; electromagnetic interference; line impedance stabilization network; power converter; Current measurement; Electromagnetic interference; Frequency measurement; Impedance; Impedance measurement; Noise; Power electronics; EMI; LISN; conducted emissions; electromagnetic interference;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Technology (ICIT), 2013 IEEE International Conference on
  • Conference_Location
    Cape Town
  • Print_ISBN
    978-1-4673-4567-5
  • Electronic_ISBN
    978-1-4673-4568-2
  • Type

    conf

  • DOI
    10.1109/ICIT.2013.6505745
  • Filename
    6505745