DocumentCode
2014859
Title
Non intrusive fault detection through electromagnetism analysis
Author
Thomas, Sébastien ; Regis, Didier ; Faura, David ; Gatti, Marc ; Duc, Guillaume ; Danger, Jean-Luc
Author_Institution
Telecom ParisTech, Inst. Telecom, Paris, France
fYear
2011
fDate
5-9 Sept. 2011
Firstpage
1
Lastpage
8
Abstract
In this paper we introduce a fully non intrusive test method which is based on the Differential Electro-Magnetic Analysis (EMA). Our objective is to demonstrate the capability of this new method to detect stuck-at-0 faults voluntary injected in a full-custom circuit. This detection is carried out by comparing a reference trace, called Reference Signature, with a differential trace representing the observed electromagnetic activity. The results show the efficiency of the proposed method. We will then introduce the possibility offered by EM measurement to be used to detect degradation of physical parameters on equipments where no intrusions are allowed.
Keywords
electromagnetism; fault diagnosis; field programmable gate arrays; integrated circuit reliability; logic testing; differential electromagnetism analysis; differential trace; field programmable gate arrays; integrated circuit reliability; nonintrusive fault detection; reference signature; reference trace; stuck-at-0 fault detection; Circuit faults; Databases; Electromagnetics; High definition video; Monitoring; Reliability; Sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Emerging Technologies & Factory Automation (ETFA), 2011 IEEE 16th Conference on
Conference_Location
Toulouse
ISSN
1946-0740
Print_ISBN
978-1-4577-0017-0
Electronic_ISBN
1946-0740
Type
conf
DOI
10.1109/ETFA.2011.6059065
Filename
6059065
Link To Document