• DocumentCode
    2015528
  • Title

    An Optimized Micromixer with Patterned Grooves

  • Author

    Tang, Yanghua ; Wu, Jonathan ; Czyzewska, Eva ; Stanley, Kevin

  • Author_Institution
    National Research Council
  • fYear
    2004
  • fDate
    25-27 Aug. 2004
  • Firstpage
    300
  • Lastpage
    305
  • Abstract
    With the development of microfluidic systems, there is a growing interest in micro scale laminar flow mixing. In this work, the fluid rotating angle and mixing efficiency in a micromixer with patterned grooves are studied as a function of the dimensions of the microstructure by numerical simulation. We found that mixing efficiency does not always increase with higher fluid stream rotation in the microchannel. High groove aspect ratios are not advantageous to fluid rotation. Experiments on mixture of two fluids were done on a micromixer fabricated in PDMS by replica molding. An 85% mixing efficiency was obtained in a 30mm long mixing channel with two dyed liquids.
  • Keywords
    Computational fluid dynamics; Councils; Equations; Fuel cells; Microchannel; Microfluidics; Microstructure; Numerical simulation; Soft lithography; Technological innovation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    MEMS, NANO and Smart Systems, 2004. ICMENS 2004. Proceedings. 2004 International Conference on
  • Print_ISBN
    0-7695-2189-4
  • Type

    conf

  • DOI
    10.1109/ICMENS.2004.1508965
  • Filename
    1508965