DocumentCode :
2016933
Title :
Characterization of platinum electrode using unbalanced magnetic field sputter for implantable biomedical applications
Author :
Lee, Hongseok ; Kim, Heung Bum ; Im, T.G. ; Jeong, J.I. ; Ahn, Seungyoung
Author_Institution :
Biomed. Inst., Solco Biomed. Co Ltd., Kyounggi, South Korea
fYear :
2003
fDate :
5-5 June 2003
Firstpage :
291
Abstract :
Summary form only given, as follows. Summary form only given. Platinum(Pt) is a biocompatible material which exhibits strong thermal and electrical conductivity due to its high melting point and good durability And thus it is used commonly in bio-electrodes and bio-chips. Tungsten (W) wire was coated with platinum film, and analyzed for their mechanical and biocompatibility properties. Platinum film has been deposited by magnetron sputter with unbalanced magnetic field system (UBM) experiment was performed under a variety of conditions by changing deposition temperature, bias voltage, magnetic field and deposition time in order to deduce the optimum process We examined exfoliation and sedimentation state of anode and cathode by microscope and EPMA under the test of electro-chemical corrosion using Hank´s solution and analyzed the film surface by AES survey and depth profile Film adhesion was analyzed by micro scratch tester Cross-section and diffraction was analyzed by SEM and XRD. Film showed very low impurity level, and surface and cross-section of the film is elaborate It also did not have sedimentation in film, and the crystallization in [110], [200], [220] and [222] was observed. However at high current density (800mA/cm/sup 2/) sedimentation was observed in corrosion test.
Keywords :
X-ray diffraction; adhesion; biomedical electrodes; biomedical materials; corrosion; corrosion protective coatings; crystallisation; electron probe analysis; metallic thin films; platinum; scanning electron microscopy; sputter deposition; sputtered coatings; surface composition; tungsten; Auger electron spectra; Hank´s solution; Pt; Pt electrode; Pt film; W; W-Pt; X-ray diffraction; anode; bias voltage; biocompatible material; cathode; cross-section; deposition temperature; deposition time; depth profile; durability; electrical conductivity; electro-chemical corrosion; electron probe microanalysis; exfoliation state; film adhesion; implantable biomedical applications; magnetron sputter; mechanical properties; micro scratch tester; optimum process; scanning electron microscopy; sedimentation state; thermal conductivity; unbalanced magnetic field sputter; unbalanced magnetic field system experiment; Biomedical electrodes; Corrosion; Magnetic analysis; Magnetic fields; Magnetic films; Performance analysis; Platinum; Scanning electron microscopy; System testing; Thermal conductivity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science, 2003. ICOPS 2003. IEEE Conference Record - Abstracts. The 30th International Conference on
Conference_Location :
Jeju, South Korea
ISSN :
0730-9244
Print_ISBN :
0-7803-7911-X
Type :
conf
DOI :
10.1109/PLASMA.2003.1228849
Filename :
1228849
Link To Document :
بازگشت