• DocumentCode
    2017255
  • Title

    A new multi-unit acquisition system for free-moving animal using field programmable analog array and on chip MCU-Neuroscope1

  • Author

    Yamamoto, Jun ; Anzai, Yuichiro ; Tsukada, Minoru

  • Author_Institution
    Dept. of Comput. Sci., Keio Univ., Yokohama, Japan
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    113
  • Abstract
    We designed a new multi-unit acquisition system for free-moving animals which breaks through the constraint of conventional multi-unit recording systems. To release those animals from thick electronic wires during experimentation, the IrDA infrared data communication, field programmable analog array (MPAA020) and 16 bit micro processor (H8), were used for the design. We summarize the related works for multi-unit recording techniques and point out the defects of those old techniques. Then the design of the system are introduced. As the results of the research, we checked the fidelity of recorded neural activity and the reliability of the data transmission
  • Keywords
    analogue circuits; biology computing; data acquisition; field programmable gate arrays; microelectrodes; neural nets; neurophysiology; zoology; 16 bit micro processor; H8; IrDA infrared data communication; MPAA020; Neuroscope1; data transmission reliability; electronic wires; field programmable analog array; free-moving animal; multi-unit acquisition system; multi-unit recording techniques; on chip MCU; recorded neural activity; Animals; Computer science; Data communication; Design engineering; Electrodes; Field programmable analog arrays; Implants; Neurons; System-on-a-chip; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Neural Information Processing, 1999. Proceedings. ICONIP '99. 6th International Conference on
  • Conference_Location
    Perth, WA
  • Print_ISBN
    0-7803-5871-6
  • Type

    conf

  • DOI
    10.1109/ICONIP.1999.843971
  • Filename
    843971