DocumentCode
2017801
Title
Effect of packaging asymmetry on the performance of a 2D MEMS thermal wind sensor with different heating geometries
Author
Zhu, Yan-qing ; Su, Ling ; Chen, Bei ; Qin, Ming ; Huang, Jian-qiu ; Huang, Qing-an
Author_Institution
Key Laboratory of MEMS of Ministry of Education, Southeast University, Nanjing, 210096, China
fYear
2015
fDate
11-14 Aug. 2015
Firstpage
201
Lastpage
204
Abstract
In this paper, the effect of packaging asymmetry on the performance of a 2D MEMS thermal wind sensor with different heating geometries is investigated quantitatively for the first time. The thermal wind sensor is fabricated on a silicon-in-glass (SIG) substrate with anisotropic thermal conductivity by a lift-off process. The silicon vias embed in the glass are employed to exchange heat between the device and the airflow, whereas the glass is used to reduce the invalid heat loss and improve the sensitivity of the sensor chip. In the experiment, the wind sensor was operated by using different heating geometries, which are respectively annular heating geometry, square heating geometry and hybrid heating geometry. Measurement results show that, with different heating geometries (annular, square and hybrid), the mean square errors of the output voltage versus wind direction (0–360 degrees) of the sensor at 30 m/s are respectively 5 mV, 25 mV and 11.67 mV before compensation. The corresponding average direction errors of the sensor are respectively 3.42, 11 and 5.79 degrees. It can be seen that the thermal wind sensor with annular heater geometry is less susceptible to package errors.
Keywords
Geometry; Heating; Measurement uncertainty; Mechanical variables measurement; Performance evaluation; heating geometries; micromachined; packaging asymmetry; thermal wind sensor;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Packaging Technology (ICEPT), 2015 16th International Conference on
Conference_Location
Changsha, China
Type
conf
DOI
10.1109/ICEPT.2015.7236575
Filename
7236575
Link To Document