DocumentCode
2021152
Title
Design and construction of a diagnostic beamline for the Princeton PBX-M experiment
Author
Gray, I.L.S. ; Coupland, J.R. ; Hopkins, M. ; Martel, K.P. ; Mepham, J.W. ; Preest, A.A. ; Stanmore, B.J. ; Kugel, H.W. ; Kaita, R.
Author_Institution
Culham Lab., UKAEA, Abingdon, UK
fYear
1989
fDate
2-6 Oct 1989
Firstpage
149
Abstract
An 80 kV, 2.7 A, diagnostic beamline for use on the PBX-M tokamak is described. The 4 m focal length H beam of 0.5° divergence has a full energy current density of 5 mA/cm2 at the focal plane. The beamline was designed without any development work, fabricated, tested, installed, and commissioned ahead of schedule. The design and manufacture of the beamline are detailed, and management of the project is described
Keywords
fusion reactor theory and design; Princeton PBX-M experiment; design; diagnostic beamline; manufacture; tokamak; Contracts; Current density; Laboratories; Laser excitation; Particle beam injection; Physics; Plasma density; Plasma diagnostics; Plasma sources; Pulse modulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1989. Proceedings., IEEE Thirteenth Symposium on
Conference_Location
Knoxville, TN
Type
conf
DOI
10.1109/FUSION.1989.102193
Filename
102193