DocumentCode :
2032115
Title :
A study on a preventive system of wire break triggered by direct lightning strokes on to DC railway feeding systems
Author :
Morimoto, Hiroaki ; Yoshii, Tsurugi ; Makimoto, Jiro ; Yoshizumi, Hiroshi ; Nishiwaki, Atsushi ; Hayashiya, Hitoshi
Author_Institution :
Power Supply Technol. Div., Railway Tech. Res. Inst., Tokyo, Japan
fYear :
2012
fDate :
2-7 Sept. 2012
Firstpage :
1
Lastpage :
5
Abstract :
The wires of DC electric railway feeding circuit may be broken by a direct lightning stroke. This kind of trouble occurs not so frequently; however, once it occurs, it makes a great disturbance of train operation. We assumed the process of wire break, and we are now studying a new preventive system of wire break caused by ground faults triggered by lightning strokes. The result of basic test shows the possibility of detecting such ground faults before the break of the wire; however, there remain some problems which should be solved before practical system construction.
Keywords :
lightning protection; railway electrification; DC electric railway feeding circuit; direct lightning strokes; ground faults; train operation; wire break preventive system; Arresters; Corrosion; Lightning; Resistance; Substations; Varistors; Zinc oxide; arc horn; dc electric railway; ground fault; ground wire; protective wire; wire break;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Lightning Protection (ICLP), 2012 International Conference on
Conference_Location :
Vienna
Print_ISBN :
978-1-4673-1898-3
Electronic_ISBN :
978-1-4673-1896-9
Type :
conf
DOI :
10.1109/ICLP.2012.6344306
Filename :
6344306
Link To Document :
بازگشت