• DocumentCode
    2033155
  • Title

    Preinstallation testing of TFTR long pulse ion sources correlated with reliability

  • Author

    Wright, Kenneth E.

  • Author_Institution
    Plasma Phys. Lab., Princeton Univ., NJ, USA
  • fYear
    1989
  • fDate
    2-6 Oct 1989
  • Firstpage
    412
  • Abstract
    The operational performance of the long-pulse ion sources (LPISs) installed and operated on the Tokamak Fusion Test Reactor (TFTR) neutral beam injection system has been compared with preinstallation test data. A direct correlation between unsatisfactory performance and/or failure and preinstallation test results can be made. Upon disassembly of the LPISs, causes for the failure were found. Improved cleaning processes and inspection procedures have been implemented. More stringent testing during the assembly phase and stricter acceptance criteria for preinstallation tests have helped avoid failures. The more stringent procedures are discussed, preinstallation test data is presented, and operational reliability is described
  • Keywords
    Tokamak devices; fusion reactor instrumentation; ion sources; TFTR long pulse ion sources; Tokamak Fusion Test Reactor; assembly phase; cleaning processes; failure; inspection; neutral beam injection system; operational reliability; preinstallation test data; Apertures; Assembly; Ion sources; Magnetic confinement; Particle beam injection; Particle beams; Plasma accelerators; Plasma confinement; Plasma sources; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1989. Proceedings., IEEE Thirteenth Symposium on
  • Conference_Location
    Knoxville, TN
  • Type

    conf

  • DOI
    10.1109/FUSION.1989.102252
  • Filename
    102252