• DocumentCode
    2036195
  • Title

    Modular Conventional Protection and its Enhancemen through Electronic Circuit Breaker Systems

  • Author

    Mehl, Richard ; Meckler, Peter

  • Author_Institution
    E-T-A GmbH
  • fYear
    2005
  • fDate
    Sept. 2005
  • Firstpage
    65
  • Lastpage
    70
  • Abstract
    Conventional mechanical circuit breakers protect AC and DC circuits from overload and short circuit conditions, and also meet the required physical isolation criteria after contact separation. They are limited in life because of mechanical degradation. Existing ESS\´s1) are hybrid devices that combine the advantages of mechanical circuit breakers that offer lower contact resistance and power loss with electronic remote control functions. Electronic circuit breakers are capable of offering features such as almost unlimited short circuit capacity, programmability of rated current and trip time curve characteristics, wire break indication, and millions of operating cycles without any degradation. Protection against field induced electromagnetic pulses need additional shielding. For this reason, electronic circuit breakers often use an electrical contact in series with the power semiconductor which will stay open and in the "OFF"-state, thus withstanding the required isolation voltages. Differences between both types of circuit breakers are discussed in detail based on specific test results and applications. For high DC voltage applications conventional circuit breakers need large air gaps, a sophisticated arc extinguishing method or they use expensive technologies like vacuum or gas filled switching chambers. ESS can meet the requirements in size and performance, but they also need an electrical contact for isolation. We must therefore conclude, that electronic circuit breakers often need electrical contacts.
  • Keywords
    air gaps; arcs (electric); circuit breakers; contact resistance; electrical contacts; electromagnetic pulse; short-circuit currents; air gaps; arc extinguishing method; contact resistance; electronic circuit breaker systems; electronic contact separation; electronic remote control functions; field induced electromagnetic pulses; gas filled switching chambers; high DC voltage applications; mechanical circuit breakers; overload protection; physical isolation criteria; power loss; power semiconductors; short circuit protection; trip time curve characteristics; Circuit breakers; Circuit testing; Contact resistance; Degradation; Electromagnetic fields; Electromagnetic shielding; Electronic circuits; Power system protection; Voltage; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Conference, 2005. INTELEC '05. Twenty-Seventh International
  • Conference_Location
    Estrel Hotel, Berlin, Germany
  • Print_ISBN
    978-3-8007-2905-0
  • Type

    conf

  • DOI
    10.1109/INTLEC.2005.335195
  • Filename
    4134308