• DocumentCode
    2044700
  • Title

    Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range

  • Author

    Kaindl, A. ; Nowak, S. ; Koschnitzki, T. ; Borsi, H.

  • Author_Institution
    Siemens Med. Eng., Erlangen, Germany
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    168
  • Lastpage
    171
  • Abstract
    In order to analyze the partial discharge signal noise in the radio frequency range, the signal characteristics of partial discharge pulses generated in a large-scale epoxy-resin impregnated coil are analyzed in this paper and compared with the partial discharge behavior at lower frequencies. Partial discharge inception voltages generally are higher when measured at radio frequency level compared to standard measurements. Two different pulse types, single and double pulses or different void types account for the variations in the partial discharge behavior
  • Keywords
    coils; epoxy insulation; impregnated insulation; partial discharge measurement; RF signal noise analysis; epoxy resin impregnated coil; partial discharge measurement; Character generation; Frequency measurement; Noise generators; Partial discharge measurement; Partial discharges; Pulse generation; RF signals; Radio frequency; Signal analysis; Signal generators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 2000. Conference Record of the 2000 IEEE International Symposium on
  • Conference_Location
    Anaheim, CA
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-5931-3
  • Type

    conf

  • DOI
    10.1109/ELINSL.2000.845481
  • Filename
    845481