• DocumentCode
    2045369
  • Title

    Radiation thermometry for high-temperature liquid stream at blast furnace

  • Author

    Sugiura, Masato ; Ootani, Youhei ; Nakashima, Masato

  • Author_Institution
    Environ. & Process Technol. R&D Center, Nippon Steel Corp., Chiba, Japan
  • fYear
    2011
  • fDate
    13-18 Sept. 2011
  • Firstpage
    472
  • Lastpage
    475
  • Abstract
    Temperature measurement of iron-slag-mixed liquid tapped from a blast furnace taphole is essential for understanding the inner thermal condition. The temperature is generally measured by a disposable thermocouple. Radiation thermometry has the advantage of non-contact sensing. In this paper, we report the thermal radiation model of semitransparent slag on the tapped stream and experimental result of slag temperature measurement focusing on the highest intensity of the thermal image.
  • Keywords
    blast furnaces; heat radiation; high-temperature techniques; iron; slag; temperature measurement; thermocouples; thermometers; waste disposal; blast furnace; disposable thermocouple; high-temperature liquid stream; iron slag mixed liquid; radiation thermometry; semitransparent slag; slag temperature measurement; taphole; thermal radiation model; Blast furnaces; Cameras; Iron; Slag; Streaming media; Temperature; Temperature measurement; Blast Furnace; High Temperature; Iron; Radiation Thermometry; Slag;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE Annual Conference (SICE), 2011 Proceedings of
  • Conference_Location
    Tokyo
  • ISSN
    pending
  • Print_ISBN
    978-1-4577-0714-8
  • Type

    conf

  • Filename
    6060703