• DocumentCode
    2045654
  • Title

    Operative physico-chemical diagnostics of SF6-equipment

  • Author

    Arakelian, Vadim G. ; Kovalenko, Alex J.

  • Author_Institution
    Electrotech. Inst., Moscow, Russia
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    320
  • Lastpage
    323
  • Abstract
    Physico-chemical methods are the basis of operating methods of diagnostics of SF6-equipment. Criteria of limiting conditions are formed using data from the analysis of humidity and acidity of SF 6. Using these data residual resource of these parameters is expected, and a level of partial discharge is calculated. Wear of the nozzle and it residual resource is determined from the concentration of CF4. Integrated leakage of SF6 is determined from analysis of the air of a ventilating exhaust
  • Keywords
    SF6 insulation; chromatography; humidity measurement; pH measurement; partial discharge measurement; reliability; SF6; SF6-equipment; acidity; chromatography; humidity; integrated leakage; limiting condition criteria; nozzle wear; operative physico-chemical diagnostics; partial discharge; residual resource; tetrafluoromethane concentration; ventilating exhaust; Automatic control; Computer crashes; Computerized monitoring; Control systems; Data analysis; Humidity; Partial discharge measurement; Partial discharges; Sulfur hexafluoride; Switches;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 2000. Conference Record of the 2000 IEEE International Symposium on
  • Conference_Location
    Anaheim, CA
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-5931-3
  • Type

    conf

  • DOI
    10.1109/ELINSL.2000.845517
  • Filename
    845517