DocumentCode
2051289
Title
The CARTOGAM portable gamma imaging system
Author
Gal, O. ; Jean, F. ; Lainé, F. ; Lévêque, C.
Author_Institution
CEA, Centre d´´Etudes Nucleaires de Saclay, Gif-sur-Yvette, France
Volume
2
fYear
1999
fDate
1999
Firstpage
725
Abstract
The CARTOGAM portable gamma camera has been developed for gamma imaging applications in nuclear facilities. Its most prominent characteristics are its mass (15 kg for the detection head, including the shied) and its size (8 cm in diameter and 40 cm in length), which make it very easy to handle. Another specificity of this camera lies in the fact that the same detector is used for both visible and gamma images, which warrants a precise correspondence between both. The industrialisation of CARTOGAM has been performed by the firm Eurisys Mesures, and the camera is now commercially available. We present here the characteristics of this device as also its performance. Afterwards we show images obtained during acquisition campaigns on various nuclear sites. Finally we introduce some additional developments that improve the camera performance and the exploitation of the images, such as image segmentation, estimate of dose rates, use of the detector in a photon counting mode
Keywords
gamma-ray detection; image segmentation; radioactivity measuring apparatus; solid scintillation detectors; CARTOGAM portable gamma imaging system; acquisition campaigns; camera performance; dose rates; gamma imaging applications; image segmentation; nuclear facilities; photon counting mode; Cameras; Collimators; Gamma ray detection; Gamma ray detectors; Head; Image segmentation; Optical imaging; Personnel; Pollution measurement; Steel;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1999. Conference Record. 1999 IEEE
Conference_Location
Seattle, WA
ISSN
1082-3654
Print_ISBN
0-7803-5696-9
Type
conf
DOI
10.1109/NSSMIC.1999.845770
Filename
845770
Link To Document