DocumentCode
2052428
Title
Harmonic measurement and modeling for mass implementation of nonlinear appliances
Author
Koch, A.S. ; Myrzik, J.M.A. ; Wiesner, T. ; Jendernalik, L.
fYear
2012
fDate
22-26 July 2012
Firstpage
1
Lastpage
6
Abstract
In order to analyze the effects of a widespread use of nonlinear appliances harmonic measurements are done on specific examples like compact fluorescent lamps (CFL) and photovoltaic (PV) inverters. The results of the investigation determine requirements on nonlinear models, which are necessary to consider the impact of mass implementation. Particularly, the voltage and operating point dependency of the harmonic currents are taken into account. Furthermore, this paper provides an overview of existing nonlinear models and emphasizes their advantages and disadvantages. Thereby, the main focus is on models, which uses a measurement based approach.
Keywords
domestic appliances; electric current measurement; fluorescent lamps; invertors; mass measurement; CFL; PV inverter; compact fluorescent lamp; harmonic current dependency; harmonic measurement; harmonic modeling; mass implementation; nonlinear appliance; photovoltaic inverter; Current measurement; Distortion measurement; Harmonic analysis; Harmonic distortion; Inverters; Power system harmonics; Voltage measurement; Harmonic measurements; nonlinear models;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Society General Meeting, 2012 IEEE
Conference_Location
San Diego, CA
ISSN
1944-9925
Print_ISBN
978-1-4673-2727-5
Electronic_ISBN
1944-9925
Type
conf
DOI
10.1109/PESGM.2012.6345068
Filename
6345068