Abstract
Chemical mechanical polishing (CMP) process is widely used for global planarization of inter-level dielectric (ILD) for sub-micron technology. But the hot-spot due to partial over-polishing was generated in the edge of wafers, and became a major concern. Thus, it is very important to understand the correlation between ILD-CMP process and various facility factors of CMP equipment system. With facility shortage of deionized water (DIW) pressure, we introduced an adding purified N 2 (PN2) gas in polishing head cleaning station for increasing a cleaning effect. Our experimental results show that DIW pressure and PN2 gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and PN2 gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% of wafer edge over-polishing. Finally, we suggest that the facility factors supplied to equipment system play an important role in ILD-CMP process
Keywords
chemical mechanical polishing; dielectric thin films; metallisation; surface cleaning; H2O; N2; chemical-mechanical polishing; cleaning effect; deionized water pressure; equipment system; facility factor; global planarization; hot spot; inter-level dielectric; purified nitrogen gas; sub-micron technology; wafer edge over-polishing; Chemical processes; Chemical technology; Cleaning; Dielectrics; Glass; Manufacturing processes; Planarization; Silicon; Slurries; Smoothing methods;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 2001. (ISEIM 2001). Proceedings of 2001 International Symposium on
Conference_Location
Himeji
Print_ISBN
4-88686-053-2
Type
conf
DOI
10.1109/ISEIM.2001.973573
Filename
973573
Link To Document