Abstract
This paper analyzes the parameters of power-supply network and the harmonic characteristics of loads by researching the structures and operation ways of traction power-supply system of the train. It also analyzes and compares the current methods in removing current harmonics. Eventually, it comes up with the way using chain high-voltage APF to eliminate the harmonics. This paper describes the main circuit design and control strategy, among which the key technologies are chain APF harmonic detection algorithm, phase-splitting instantaneous current control and balanced DC voltage control. It builds up a simulation model based on actual parameters, and the simulation results show the compensation waveforms and effects which proves the project is feasible and effective.
Keywords
active filters; electric current control; harmonics suppression; network synthesis; power filters; railways; traction power supplies; voltage control; APF harmonic detection algorithm; balanced DC voltage control; chain high-voltage APF; circuit design; compensation waveform; current harmonics elimination; high-voltage active power filter; load harmonic characteristics; phase-splitting instantaneous current control; power-supply network parameter; traction power-supply system; train;
fLanguage
English
Publisher
ieee
Conference_Titel
Electricity Distribution (CICED), 2012 China International Conference on
Conference_Location
Shanghai
ISSN
2161-7481
Print_ISBN
978-1-4673-6065-4
Electronic_ISBN
2161-7481
Type
conf
DOI
10.1109/CICED.2012.6508434
Filename
6508434
Link To Document