Abstract :
Electrowetting-on-dielectric (EWOD) is a new method for moving liquids in micro-total-analysis system. One of the biggest challenges for all EWOD-based biofluidic chips is preventing and minimizing nonspecific adsorption of biomolecules on the hydrophobic surfaces. In this paper, we theoretically and experimentally analyze the adsorption in EWOD, which is mainly induced by hydrophobic interaction and electrostatic attraction. An open-configuration EWOD with only one hydrophobic surface, instead of the traditional sandwiched EWOD with two hydrophobic surfaces, is exploited to minimize the hydrophobic interaction. The manipulation modes are also optimized to decrease electrostatic attraction by limiting the duty-ratio of the applied pulse voltage. In experiments, the analyte is a 1:1 (v/v) mixture of 10 mug/ml bovine serum albumin (BSA) solution with pH 7.4 phosphate buffers and 10 mug/ml hen egg white lysozyme solution with pH 7.4 phosphate buffers. A rapid transportation speed of the 1.5 mul mixture droplet as high as 14 mm/s is successfully achieved in air by applying a 2.5 Hz 40 Vdc pulse voltage with the 12.5% duty-ratio. The fabrication process of the silicon-substrate actuator is IC compatible, thus a miniaturized biofluidic system integrated with peripheral circuits is technically feasible
Keywords :
adsorption; bioMEMS; biomolecular effects of radiation; microactuators; microfluidics; micromanipulators; wetting; 14 mm/s; 2.5 Hz; 40 V; BSA solution; EWOD adsorption; EWOD method; applied pulse voltage duty-ratio limiting; bovine serum albumin solution; electrostatic attraction; electrowetting based biofluidic actuation; electrowetting-on-dielectric method; hen egg white lysozyme solution; hydrophobic interaction; manipulation modes; micro-total-analysis system; miniaturized biofluidic system; nonspecific biomolecular adsorption prevention; open configuration biofluidic actuation; peripheral circuit integration; phosphate buffers; silicon-substrate actuator fabrication process; transportation speed; Dielectric constant; Electrodes; Electrostatics; Equations; Fabrication; Liquids; Molecular biophysics; Petroleum; Proteins; Voltage; biofluidics; biomolecular adsorption; electrowetting;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nano/Micro Engineered and Molecular Systems, 2006. NEMS '06. 1st IEEE International Conference on
Conference_Location :
Zhuhai
Print_ISBN :
1-4244-0139-9
Electronic_ISBN :
1-4244-0140-2
Type :
conf
DOI :
10.1109/NEMS.2006.334669
Filename :
4135151
Link To Document :
بازگشت