DocumentCode
2059137
Title
Non-contact measurement of thickness uniformity of chemically etched Si membranes by fiber-optic low-coherence interferometry
Author
Djinovic, Zoran ; Tomic, Milos ; Manojlovic, Lazo ; Lazic, Zarko ; Smiljanic, Milce M.
Author_Institution
Inst. of Sensor & Actuator Syst., Vienna Univ. of Technol., Vienna
fYear
2008
fDate
11-14 May 2008
Firstpage
321
Lastpage
324
Abstract
In this paper we present a contactless technique for thickness measurement of chemically etched Si membranes. This technique is based on low-coherence interferometry performed by single-mode fiber-optic sensing configuration. We are able to measure the thickness of Si membranes with accuracy of about 40 nm. We used the proposed technique for the fast measurement of thickness uniformity of central position of Si membranes with overall dimensions of 2times2 mm2 all around one 3 inch {100} Si wafer with starting thickness of 380 mum. Additionally, we measured the thickness uniformity of several membranes with central boss by scanning. The accuracy of the technique is about 100 nm.
Keywords
etching; fibre optic sensors; light interferometry; membranes; silicon; thickness measurement; Si; chemically etched Si membrane; fiber-optic low-coherence interferometry; noncontact measurement; single-mode fiber-optic sensing configuration; thickness uniformity measurement; Biomembranes; Chemicals; Etching; Microelectronics; Optical interferometry; Optical sensors; Piezoresistance; Production; Spectroscopy; Thickness measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Microelectronics, 2008. MIEL 2008. 26th International Conference on
Conference_Location
Nis
Print_ISBN
978-1-4244-1881-7
Electronic_ISBN
978-1-4244-1882-4
Type
conf
DOI
10.1109/ICMEL.2008.4559286
Filename
4559286
Link To Document