• DocumentCode
    2059357
  • Title

    Degradation diagnosis of large stator winding insulation based on ultra-wide band partial discharge detecting technique

  • Author

    Jia, Z.D. ; Xie, H.K.

  • Author_Institution
    Tsinghua Univ., Beijing, China
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    697
  • Lastpage
    700
  • Abstract
    There are two topics that are of particular interest to the workers in the field of partial discharge (PD). One is the impact of a wide variety of statistical tools on the interpretation of discharge data obtained with standard PD detection apparatus according to IEC 270. The other is the study of discharge-induced degradation processes by looking into the physics of the discharge process. Ultra-wide band (UWB) PD detecting technique is introduced to measure the PD pulse of the bar sample during aging. The data obtained are analyzed using joint time-frequency analysis (JTFA) methods, that is, short-time fourier transformation (STFT), Wigner distribution (DWD) and Gabor spectrogram (DGS), and finally Gabor spectrum is selected to analyze the characteristics of single impulse wave in different aging period. The results of analysis indicate that following the increasing of aging time, the high-frequency component of single impulse wave continuously increased, while the energy of discharge alternated from low-frequency long time lag to high-frequency short time lag and high-frequency long time lag
  • Keywords
    Fourier transforms; Wigner distribution; ageing; electric generators; insulation testing; machine insulation; machine testing; machine theory; partial discharge measurement; stators; time-frequency analysis; Gabor spectrogram; IEC 270; PD; Wigner distribution; aging characteristics; generator stator winding insulation degradation diagnosis; high-frequency long time lag; high-frequency short time lag; joint time-frequency analysis methods; low-frequency long time lag; short-time Fourier transformation; single impulse wave; statistical tools; ultra-wide band partial discharge detecting technique; Aging; Data analysis; Degradation; IEC standards; Insulation; Partial discharges; Physics; Pulse measurements; Stator windings; Time frequency analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 2001. (ISEIM 2001). Proceedings of 2001 International Symposium on
  • Conference_Location
    Himeji
  • Print_ISBN
    4-88686-053-2
  • Type

    conf

  • DOI
    10.1109/ISEIM.2001.973773
  • Filename
    973773