• DocumentCode
    2061070
  • Title

    World to Chip Sample Introduction

  • Author

    Bradley, W.W. ; Gordon, M.H.

  • Author_Institution
    Univ. of Arkansas, Fayetteville
  • fYear
    2007
  • fDate
    20-22 April 2007
  • Firstpage
    424
  • Lastpage
    431
  • Abstract
    The effort to pursue a greater quality of life has given rise to an entire industry devoted to acquiring technology that produces accurate medical diagnoses in a shorter amount of time than is currently possible. The goal is a very small, self contained system that is available to doctors in offices and to medical personnel in field situations. This goal has nearly been realized through recent advances in micro and nano technologies that allow diagnostic systems to shrink to the size of a microchip. However, as systems shrink in size, smaller sample introduction methods are needed. This paper explores three different possibilities for introducing sample from the macro environment to that of a micro-chip in a Micro Total Analysis (mu-TAS), or Lab-on-Chip (LOC), scenario. In addition to the world-to-chip possibilities, this paper also explores methods to maximize the quantity of sample delivered to specific locations on the chip for processing, while minimizing the chip area. The use of a fixed displacement, solenoid activated micropump, is verified as one method of sample entry. Standard Luer Lock syringes were also used in conjunction with Luer to 1/8 NPT fittings. Finally Hamilton micro syringes were used with UpChurch fluidic interconnects. The chip layouts included several different angles of intersection between two channels, as well as the use of multiple, smaller channels. The three methods are judged on ease of consumer use, ease of manufacturing, and finally overall reliability of the method. Preliminary results indicate that the micropump solution is the easiest for consumer use, is reliable, but is difficult to implement. The Luer lock fittings also provide easy consumer use; however, reliable sealing in combination with the shear volume of the syringes hinder implementation. Finally the Hamilton micro syringes in conjunction with UpChurch fluidic interconnects is difficult for personnel in the field to implement, but offers a reliable and easily implement- ed method of sample introduction.
  • Keywords
    biological techniques; biomedical equipment; integrated circuit economics; integrated circuit interconnections; integrated circuit reliability; integrated circuit yield; micropumps; nanobiotechnology; patient diagnosis; seals (stoppers); Hamilton micro syringes; UpChurch fluidic interconnects; consumer use; diagnostic systems; lab-on-chip analysis; manufacturing; medical diagnoses; medical microtechnology; medical nanotechnology; micro total analysis; microchip; reliable sealing; solenoid activated micropump; standard Luer Lock syringes; syringe hinder implementation; world-to-chip possibility; Fitting; Lab-on-a-chip; Magnetohydrodynamics; Medical diagnosis; Medical diagnostic imaging; Medical services; Microfluidics; Micropumps; Personnel; Polymers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Region 5 Technical Conference, 2007 IEEE
  • Conference_Location
    Fayetteville, AR
  • Print_ISBN
    978-1-4244-1280-8
  • Electronic_ISBN
    978-1-4244-1280-8
  • Type

    conf

  • DOI
    10.1109/TPSD.2007.4380401
  • Filename
    4380401