DocumentCode
2061925
Title
Performance analysis of the piezoelectric vibratory gyroscope
Author
Marinushkin, Pavel S.
Author_Institution
Siberian Fed. Univ., Krasnoyarsk, Russia
fYear
2010
fDate
9-11 Dec. 2010
Firstpage
29
Lastpage
32
Abstract
The performance of a piezoelectric vibratory gyroscope has been studied in various temperature conditions by means of the modified analytical model. Influence of temperature on the scale factor, sensitivity and shift of the operating frequency of the gyroscope has been shown. The results of modelling allow increasing accuracy and overall performance of a piezoelectric vibrating gyroscope due to analytical compensation of temperature-induced errors.
Keywords
error compensation; gyroscopes; piezoelectric devices; temperature; vibrations; gyroscope sensitivity; operating frequency shift; piezoelectric vibratory gyroscope; scale factor; temperature induced error compensation; Analytical models; Gyroscopes; Resonant frequency; Sensitivity; Temperature; Temperature sensors; Vibrations; Microelectromechanical systems (MEMS); piezoelectric gyroscope; vibratory gyroscope;
fLanguage
English
Publisher
ieee
Conference_Titel
Fundamental Problems of Micro/Nanosystems Technologies (MNST), 2010 IEEE 2nd Russia School and Seminar on
Conference_Location
Novosibirsk
Print_ISBN
978-1-4244-5962-9
Electronic_ISBN
978-1-4244-5963-6
Type
conf
DOI
10.1109/MNST.2010.5687131
Filename
5687131
Link To Document