DocumentCode
2064524
Title
Neutral injection for TEXTOR
Author
Euringer, H. ; Lochter, M. ; Pfister, U. ; Uhlemann, R.
Author_Institution
Inst. fuer Plasmaphys., KFA Julich, GmbH, West Germany
fYear
1989
fDate
2-6 Oct 1989
Firstpage
991
Abstract
Two neutral beam lines have been built for coinjection and counterinjection into TEXTOR. The rated data for one beam line are 55 kV, 88 A (i.e. 4.8 MW) over 10 s for H2. The neutral injectors use cooled galvano-grids, cryopumps, and new solutions for the beam-dumps and power supplies. The components are described in detail. The measuring methods for the beam quality and the results are given, as well as some results from TEXTOR during neutral beam injection
Keywords
Tokamak devices; cryopumping; plasma heating; power supplies to apparatus; 10 s; 4.8 MW; 55 kV; H2 beam; TEXTOR; beam quality; beam-dumps; coinjection; counterinjection; cryopumps; galvano-grids; neutral beam injection; power supplies; Data mining; Hydrogen; Ion sources; Plasmas; Power supplies; Switches; Testing; Thyristors; Transformers; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1989. Proceedings., IEEE Thirteenth Symposium on
Conference_Location
Knoxville, TN
Type
conf
DOI
10.1109/FUSION.1989.102384
Filename
102384
Link To Document