DocumentCode :
2065105
Title :
Applying a metric space to design a primary transducer or electromagnetic flow meter for open channels
Author :
Michalski, Andrzej ; Piotrowski, Wieslaw
Author_Institution :
Inst. of the Theor. of Electr. Eng. & Electr. Meas., Warsaw Univ. of Technol., Poland
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
318
Abstract :
This paper deals with a problem of selecting an appropriate liquid level as a parameter in designing the exciting coil of electromagnetic (EM) flow meter. The influence of variable liquid level on transfer function of EM flow meter is explained. The method of selecting the optimal liquid level utilising the metric spaces is described. Some examples of metrics and the results of numerical calculations are presented. With this method, the transfer function of EM flow meter can be significantly improved
Keywords :
channel flow; coils; electromagnetic devices; flowmeters; transducers; electromagnetic flow meter; exciting coil; liquid level; metric space; numerical calculations; open channels; optimal liquid level; primary transducer; transfer function; variable liquid level; Coils; Electrodes; Electromagnetic measurements; Extraterrestrial measurements; Magnetic field measurement; Magnetic flux density; Shape; Space technology; Transducers; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2000. IMTC 2000. Proceedings of the 17th IEEE
Conference_Location :
Baltimore, MD
ISSN :
1091-5281
Print_ISBN :
0-7803-5890-2
Type :
conf
DOI :
10.1109/IMTC.2000.846877
Filename :
846877
Link To Document :
بازگشت