DocumentCode :
2065155
Title :
Design of arc Flash protection system using solid state switch, photo detection, with parallel impedance
Author :
Panetta, S.
Author_Institution :
I-Gard Corp., Mississauga, ON, Canada
fYear :
2013
fDate :
11-15 March 2013
Firstpage :
211
Lastpage :
213
Abstract :
Arc flash hazard has been a major concern for the electrical industry with incidences hospitalizing workers and severely impacting processes and profitability with lost production. It is well understood that the energy produced by an arc flash incident is proportional to the voltage, current and duration of the event. The arc flash duration is the sum of the time to detect the arc and the time to isolate. Breakthroughs have been achieved in the detection of arc flash incidences under 1 ms with photo detection and solid state technologies, however, conventional circuit breaker operation time is 84 ms and results in damages to equipment and injury to personnel. This paper describes an arc Flash protection system that has been designed that allows the detection of an arcing event by performing continuous light monitoring of the switchgear combined with a means to isolate the fault in under 9 ms with an SCR switch. The conceptual system has been developed for a 3 phase, 600 Volt system and is scalable to higher ratings. The module comprises a solid state SCR switch connected in parallel with a resistance for switching transient elimination, and combined with control circuitry connected to the system and fibre optic point sensors monitoring for arcing incidence. The system achieves high yield in incident energy limitation during an arc flash fault. Details of the development of the module are discussed.
Keywords :
circuit breakers; circuit-breaking arcs; fibre optic sensors; thyristors; 3 phase system; arc flash duration; arc flash fault; arc flash hazard; arc flash incident; arc flash protection system; arcing event; arcing incidence; circuit breaker; continuous light monitoring; control circuitry; electrical industry; fibre optic point sensors monitoring; incident energy limitation; operation time; parallel impedance; photo detection; solid state SCR switch; solid state technologies; switchgear; switching transient elimination; time 84 ms; time 9 ms; voltage 600 V; Arc discharges; Circuit breakers; Optical switches; Solids; Thyristors; Transient analysis; Arc Protection; Optical detection; SCR Fast Acting Switch; Switching Transients;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Safety Workshop (ESW), 2013 IEEE IAS
Conference_Location :
Dallas, TX
ISSN :
2326-3288
Print_ISBN :
978-1-4673-3040-4
Electronic_ISBN :
2326-3288
Type :
conf
DOI :
10.1109/ESW.2013.6509026
Filename :
6509026
Link To Document :
بازگشت