Abstract :
Double ridge horns with frequency 200MHz to 1GHz are hard to be transfer to calibration sites for measuring 1mAF because of its´ big dimension. In order to solve the problem, three different approaches at local custom EMC testing chamber are provided in the paper and several experiments have been done. Comparison the measurement results of custom´s EMC testing chamber with calibration value, a good agreement has obtained in transfer antenna method with the maximum discrepancy being 2.0 dB at 950MHz.
Keywords :
UHF antennas; calibration; electromagnetic compatibility; horn antennas; EMC testing chambers; antenna factor measurements; calibration sites; calibration value; double ridge horns; frequency 200 MHz to 1 GHz; transfer antenna method; Antenna measurements; Calibration; Dipole antennas; Electromagnetic compatibility; Horn antennas; Receiving antennas; Transmitting antennas; Antenna factor; Calibration; Double ridge horn;