DocumentCode :
2065875
Title :
Conducted and radiated interference measurements in the line-pantograph system
Author :
Tellini, B. ; Macucci, M. ; Giannetti, R. ; Antonacci, G.A.
Author_Institution :
Dipt. di Sistemi Elettrici e Autom., Pisa Univ., Italy
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
457
Abstract :
We present the results of a measurement campaign aimed at investigating electromagnetic interference phenomena in the interaction between overhead railway power supply lines and pantograph. In order to obtain such data, an experimental setup was assembled in a shielded room, consisting in a short section of overhead line and a full scale pantograph. One of the most interesting results consists in the observation of a very significant (both from the qualitative and the quantitative point of view) difference between the EMI behavior in the switch-on (pantograph going up) and switch-off (pantograph going down) transients
Keywords :
electric noise measurement; electromagnetic interference; overhead line conductors; pantographs; power system transients; EMI; conducted interference measurements; electromagnetic interference; line-pantograph system; model; overhead railway power supply lines; radiated interference measurements; shielded room; switch-off transients; switch-on transients; Assembly; Electromagnetic interference; Electromagnetic measurements; Electromagnetic radiation; Electromagnetic radiative interference; Electromagnetic shielding; Power measurement; Power supplies; Rail transportation; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2000. IMTC 2000. Proceedings of the 17th IEEE
Conference_Location :
Baltimore, MD
ISSN :
1091-5281
Print_ISBN :
0-7803-5890-2
Type :
conf
DOI :
10.1109/IMTC.2000.846905