• DocumentCode
    2070023
  • Title

    Premature failures in the contacts of drawout clusters

  • Author

    Furtado, Heloísa Cunha ; Le May, Iain

  • Author_Institution
    Centro de Pesquisas de Energia Eletrica, Rio de Janeiro, Brazil
  • fYear
    1996
  • fDate
    16-20 Sept. 1996
  • Firstpage
    212
  • Lastpage
    216
  • Abstract
    Premature failures in the contacts of drawout clusters operating in a pulp mill were investigated. The initial view of the operating and maintenance personnel was that loss of contact spring force was the source of the problem. Investigation showed this to be a secondary effect caused by overheating following interruption of the electrical path and consequent arcing. The primary problem was concluded to be vibration and the inability of the assemblies to maintain contact during this.
  • Keywords
    electrical contacts; failure analysis; paper industry; arcing; contact; contact spring force; drawout cluster; overheating; premature failure; pulp mill; vibration; Arm; Assembly; Atmosphere; Circuit breakers; Contacts; Joining processes; Length measurement; Milling machines; Personnel; Springs;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Contacts, 1996. Proceedings of the Forty-Second IEEE Holm Conference on ??. Joint with the 18th International Conference on Electrical Contacts
  • Conference_Location
    Chicago, IL, USA
  • Print_ISBN
    0-7803-3578-3
  • Type

    conf

  • DOI
    10.1109/HOLM.1996.557199
  • Filename
    557199