Abstract
Purpose of weighting along with the defined weighting function for the new RMS-Average detector are introduced. Extensive comparison measurements were performed by using the required Quasi-Peak and Average detectors and the new RMS-Average detector for both conducted and radiated emission measurements to confirm the weighting function and for the definition of emission limits for the new RMS-Average detector.
Keywords
radio networks; radio receivers; RMS-average detector; conducted emission; radiated emission; weighting function; Electromagnetic compatibility;