Title :
Experience with the RMS-Average detector
Author_Institution :
Test & Meas. Div., Rohde&Schwarz GmbH&Co. KG, Munich
Abstract :
Purpose of weighting along with the defined weighting function for the new RMS-Average detector are introduced. Extensive comparison measurements were performed by using the required Quasi-Peak and Average detectors and the new RMS-Average detector for both conducted and radiated emission measurements to confirm the weighting function and for the definition of emission limits for the new RMS-Average detector.
Keywords :
radio networks; radio receivers; RMS-average detector; conducted emission; radiated emission; weighting function; Electromagnetic compatibility;
Conference_Titel :
Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility, 2008. APEMC 2008. Asia-Pacific Symposium on
Conference_Location :
Singapore
Print_ISBN :
978-981-08-0629-3
Electronic_ISBN :
978-981-08-0629-3
DOI :
10.1109/APEMC.2008.4559870