Title :
Shielding effectiveness measurement conducted in a reverberation chamber and in a GTEM cell
Author :
Jin, Koh Wee ; Tai, Y.K.R. ; Seng, Ng Yew
Author_Institution :
DSO Nat. Labs.
Abstract :
This paper presents the assessment of the shielding effectiveness (SE) measurement conducted on a shielded box using the reverberation chamber and the GTEM cell. In GTEM test, the EUT is illuminated by a plane wave of a specific field with a specific polarization, while for reverberation chamber test, the field is randomly polarized and it can illuminate the EUT from all directions with statistically uniform and isotropic field without having to rotate the EUT. The intention of this paper is to understand the characteristic of SE measurement in the reverberation chamber and compare to GTEM cell measurement, since the test electromagnetic environment in the two measurement techniques are different.
Keywords :
TEM cells; magnetic shielding; reverberation chambers; GTEM cell; plane wave; reverberation chamber; shielding effectiveness measurement; Aluminum; Anechoic chambers; Electromagnetic compatibility; Electromagnetic measurements; Particle measurements; Polarization; Resonant frequency; Reverberation chamber; TEM cells; Testing;
Conference_Titel :
Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility, 2008. APEMC 2008. Asia-Pacific Symposium on
Conference_Location :
Singapore
Print_ISBN :
978-981-08-0629-3
Electronic_ISBN :
978-981-08-0629-3
DOI :
10.1109/APEMC.2008.4559892