• DocumentCode
    2071693
  • Title

    Lightning-induced voltages on telecommunication lines in Korea

  • Author

    Oh, Ho-Seok ; Park, Dong-Chul

  • Author_Institution
    Adv. Technol. Lab., Daejeon
  • fYear
    2008
  • fDate
    19-23 May 2008
  • Firstpage
    478
  • Lastpage
    481
  • Abstract
    This paper gives the characteristics of lightning-induced voltages on the subscriber telecommunication lines. The lightning parameters such as peak voltage, rise time, decay time and steepness of the front wave were statistically analyzed from the measured results. Induced voltage measurement system to measure and collect the lightning-induced voltages from several sites of Korea was developed and installed in many central offices. The distributions of lightning-induced voltages for years and seasons were analyzed.
  • Keywords
    electromagnetic induction; electromagnetic interference; lightning; subscriber loops; telecommunication cables; voltage measurement; lightning-induced voltages; subscriber telecommunication lines; voltage measurement; Central office; Electromagnetic compatibility; Grounding; Lightning; Optical coupling; Power measurement; Subscriber loops; Surge protection; Time measurement; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility, 2008. APEMC 2008. Asia-Pacific Symposium on
  • Conference_Location
    Singapore
  • Print_ISBN
    978-981-08-0629-3
  • Electronic_ISBN
    978-981-08-0629-3
  • Type

    conf

  • DOI
    10.1109/APEMC.2008.4559916
  • Filename
    4559916