DocumentCode :
2076721
Title :
Multiresolution Approach for Non-Contact Measurements of Arterial Pulse using Thermal Imaging
Author :
Chekmenev, Sergey Y. ; Farag, Aly A. ; Essock, Edward A.
Author_Institution :
University of Louisville
fYear :
2006
fDate :
17-22 June 2006
Firstpage :
129
Lastpage :
129
Abstract :
This paper presents a novel, multiresolution (MR) approach for non-contact passive measurements of the arterial pulse along the arterial tree using thermal imaging of the most accessible regions of human face and neck. The method automatically detects Region/s Of Measurement (ROM) of the arterial pulse using the periodic nature of arterial thermal patterns. This ROM constitutes a skin area where the heat pulsation produced by an artery is most pronounced. The output of the algorithm is a descriptive arterial pulse waveform. To the best of our knowledge, our results are novel and have not been reported before. Some potential applications of this work are in the field of non-contact health state/ physiology monitoring, magnetic resonance imaging, smart rooms, polygraph testing, and intent identification.
Keywords :
Arteries; Face detection; Humans; Image resolution; Monitoring; Neck; Physiology; Pulse measurements; Read only memory; Skin;