Title :
A cost-effective solution to the single disk failure in RAID architecture
Author :
Jeon, Sanghoon ; Ahn, Byoungchul
Author_Institution :
Dept. of Comput. Eng., Yeungnam Univ., Kyungsan, South Korea
Abstract :
It is very important to recover data immediately at a single disk failure for critical applications such as multimedia storage systems, real-time systems and so on. As an efficient solution, the paper proposes a hybrid scheme to improve the performance before a failed disk is replaced with a new disk and it does not require an additional disk to recover data. The hybrid scheme is evaluated and its performance is analyzed for various request sizes using the simulation. The results show that the performance of the hybrid scheme is improved by up to 85% compared with that of RAID level 5 in the reconfigured mode
Keywords :
arrays; fault tolerant computing; magnetic disc storage; memory architecture; performance evaluation; system recovery; virtual machines; RAID architecture; cost-effective solution; data recovery; failed disk; multimedia storage systems; performance analysis; real-time systems; request sizes; simulation; single disk failure; Availability; Costs; Degradation; Fault tolerance; Protection; Redundancy;
Conference_Titel :
Communications, Computers and Signal Processing, 1997. 10 Years PACRIM 1987-1997 - Networking the Pacific Rim. 1997 IEEE Pacific Rim Conference on
Conference_Location :
Victoria, BC
Print_ISBN :
0-7803-3905-3
DOI :
10.1109/PACRIM.1997.619956