• DocumentCode
    2081863
  • Title

    Quantifying freezing of gait in Parkinson´s disease during the instrumented timed up and go test

  • Author

    Mancini, Matteo ; Priest, K.C. ; Nutt, J.G. ; Horak, F.B.

  • Author_Institution
    Dept. of Neurology, Oregon Health & Sci. Univ., Portland, OR, USA
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    1198
  • Lastpage
    1201
  • Abstract
    Over half of patients with PD eventually develop freezing of gait (FoG), an intermittent failure to initiate or maintain walking that is often associated with trembling of the legs. We tested 21 PD with FoG, 27 PD without FoG, and 21 healthy elderly people in a clinic with the Intrumented Timed Up and Go test (ITUG). FoG was quantified from the power spectral density of the antero-posterior shank acceleration from which a Frequency Ratio was calculated as the square of the total power in the 3-8 Hz band, divided by the square of the total power in the .5-3 Hz band. Spatiotemporal gait parameters calculated from synchronized gyroscopes on the two legs were also measured in these subjects. The Frequency Ratio was significantly larger in freezers than in non-freezers or control subjects. It better differentiated gait disorders between PD subjects with and without FoG than traditional gait measures such as stride length, stride velocity and double support time. The Frequency Ratio was validated as significantly correlated with self-perceived severity of gait and balance confidence. This Freezing Ratio will be useful to quantify FoG during a simple ITUG, a popular clinical test of mobility.
  • Keywords
    biomedical measurement; diseases; gait analysis; geriatrics; gyroscopes; mechanoception; medical disorders; spatiotemporal phenomena; FoG; ITUG; PD; PD subjects; Parkinson´s disease; antero-posterior shank acceleration; balance confidence; clinical test; freezing of gait; freezing ratio; frequency 0.5 Hz to 3 Hz; frequency 3 Hz to 8 Hz; frequency ratio; gait disorders; healthy elderly people; intrumented timed up and go test; leg trembling; power spectral density; self-perceived gait severity; spatiotemporal gait parameters; stride length; stride velocity; synchronized gyroscopes; walking; Acceleration; Educational institutions; Frequency control; Instruments; Legged locomotion; Parkinson´s disease; Turning; Adult; Aged; Female; Gait; Humans; Male; Middle Aged; Models, Biological; Monitoring, Physiologic; Parkinson Disease; Walking;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6346151
  • Filename
    6346151