Title :
Evaluation of shielding effectiveness on system level by electromagnetic topology based modeling
Author :
Monje, C. Alonso ; Helmers, S. ; Díez, E. Galván
Author_Institution :
Center for Quality Eng., Siemens AG, Germany
Abstract :
The confidence in shielding effectiveness (SE) measurements on enclosures according to IEC TS 61587-3 is evaluated. A methodical analysis using an electromagnetic topology (EMT) based model is carried out to find the electromagnetic (EM) critical aspects. The EMT model represents the interaction between base and auxiliary components which are necessary for testing. As shown in examples, each local coupling effect can be investigated by means of an appropriate, numerical or experimental method. It is displayed how the EMT facilitates the translation of local estimations into the global SE test result.
Keywords :
IEC standards; computational electromagnetics; electromagnetic coupling; electromagnetic shielding; EMT model; IEC TS 61587-3 evaluation; SE measurement; auxiliary component; electromagnetic topology; local coupling effect; shielding effectiveness test; Antenna measurements; Attenuation measurement; Electromagnetic compatibility; Electromagnetic measurements; Electromagnetic modeling; Electromagnetic shielding; Electronic equipment testing; IEC standards; Magnetic field measurement; Topology;
Conference_Titel :
Electromagnetic Compatibility and Electromagnetic Ecology, 2005. IEEE 6th International Symposium on
Print_ISBN :
0-7803-9374-0
DOI :
10.1109/EMCECO.2005.1513063