DocumentCode :
2083575
Title :
Evaluation of electrical insulating resins for inverter duty application
Author :
Winkeler, Mark
Author_Institution :
P.D. George Co., USA
fYear :
1997
fDate :
22-25 Sep 1997
Firstpage :
145
Lastpage :
149
Abstract :
Recently, there has been a considerable amount of research done on the use of electrical motors controlled by adjustable speed drives, often called inverters. In some instances these inverters have been shown to greatly reduce motor life. The failure mechanism has been in the insulating materials. This paper tries to give an overview of various insulating resins and their performance with standard magnet wire as well as the new `pulse resistant´ magnet wires especially designed for use with inverters
Keywords :
AC motor drives; DC-AC power convertors; electric breakdown; insulated wires; insulation testing; invertors; life testing; machine insulation; machine testing; organic insulating materials; variable speed drives; breakdown testing; electrical insulating resins; failure mechanism; insulating materials; insulation performance; inverter duty applications; motor insulation life; pulse resistant magnet wires; variable speed motor drives;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference, 1997, and Electrical Manufacturing & Coil Winding Conference. Proceedings
Conference_Location :
Rosemont, IL
ISSN :
0362-2479
Print_ISBN :
0-7803-3959-2
Type :
conf
DOI :
10.1109/EEIC.1997.651021
Filename :
651021
Link To Document :
بازگشت