• DocumentCode
    2084090
  • Title

    Stress related failures and testing of inverter driven motors

  • Author

    Anderson, Jeff ; Lebruska, Scott

  • Author_Institution
    Baker Instrum. Co., Fort Collins, CO, USA
  • fYear
    1997
  • fDate
    22-25 Sep 1997
  • Firstpage
    151
  • Lastpage
    154
  • Abstract
    When first introduced, variable frequency drives (VFDs), also known as adjustable speed drives (ASDs) seemed to be an ideal tool for use in industrial production and process applications which used induction motors as prime movers. However, several negative effects, the most drastic of which was increased motor failures, resulted. This paper discusses some of these negative effects, some possible solutions and a predictive test method designed to avert such failures of induction motor insulation
  • Keywords
    DC-AC power convertors; electric breakdown; induction motor drives; insulation testing; invertors; machine insulation; machine testing; variable speed drives; adjustable speed drives; induction motor insulation failures; industrial production processes; insulation breakdown testing; motor failures; predictive test method; prime movers; variable frequency drives;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference, 1997, and Electrical Manufacturing & Coil Winding Conference. Proceedings
  • Conference_Location
    Rosemont, IL
  • ISSN
    0362-2479
  • Print_ISBN
    0-7803-3959-2
  • Type

    conf

  • DOI
    10.1109/EEIC.1997.651023
  • Filename
    651023